Low subcool high superheat - At approximately 85 degrees Fahrenheit (29.4°C), the pressure for R-410A could be around 230-260 psi on the low side and 500-550 psi on the high side, but actual values can vary. What happens if superheat is too high? Excessive superheat can lead to reduced cooling capacity, insufficient cooling, and potential compressor issues.

 
That’s because low charge results in high superheat AND low subcooling (we have covered this in high superheat low subcooling issues here). We are left with only 2-3 culprits that can actually cause both high superheat and normal subcooling. These are: Too high indoor CFMs. Too high indoor load. Faulty measurement. Let’s look at all these 3 .... Adp pay hourly calculator

I had posted in a previous thread about the superheat reading taken on my system being about 11 *F too low (possible overcharge). Today another tech came out and measured everything again. This tech measured the subcooling as well this time. Here are the measurements he took: OAT DB: 68 *F Low side: 68 psi (39 *F) High side: 140 psi …Low subcooling for R22. Low subcooling usually means your system is undercharged or has a dirty evaporator coil. It's like running your car with low tire pressure - it won't perform well. The solution? Add refrigerant or clean the coil, depending on the issue. High subcooling for R22. High subcooling often indicates overcharging or a ...High side pressure and subcool become the determining factor in charging because of the TXVs ability to change flow rate. Superheat still can be measured though to determine if a TXV is operating properly. Some TXVs can be manually adjusted to change spring pressure and flow rate. ... Low Charge- If refrigerant charge is low, the superheat will ...8-12* superheat would be what you want to shoot for. higher the superheat, the more starved the evaporator is. you definitely have to factor in them long linesets. if you can get the superheat down to the margin, roll with it. you will know your overcharged if your superheat falls below the margin.To sum it up, high superheat and low subcooling are the two conditions that can greatly affect a system’s efficiency. They can happen when there is an undercharge of …Low Superheat Low Subcooling: Learn To Fix It. Low superheat and low subcooling are the indicators for your evaporator to be low on heat and have a limited refrigerator in its condenser. We will recommend you maintain a suitable climate around your Living area in order to feel comfortable. Tom Moore May 19, 2023 — 5 minutes read.Currently: 30psig suction/55 superheat (47 if I check at evap) 330 psig head/50 subcool, sight glass clear. Outdoor ambient: 62. Freezer temp: 34 (working its way down) TD 5 degrees. I do have a significant layer of frost on the 3 dist tubes coming off of TXV.The difference between a low-context and a high-context culture lies in the mode of communication that takes place at the individual dialogue level. In low-context cultures, such a...To use our two examples from the previous paragraph, R134a at 0 psig and -5 F has 10 degrees of superheat, and the same refrigerant at the same pressure but at -20 F has 5 degrees of subcooling. These concepts of saturation, superheat, and subcooling are the foundation of all sealed system troubleshooting.High Subcooling Causes: Low refrigerant charge (undercharged system). Restriction in the liquid line (usually ice). Indoor airflow (CFMs) is too high. Indoor heat load is too high. Metering device (TXV, AEV, or piston) is underfeeding. High refrigerant charge (overcharged system). Restriction in the liquid line (usually ice). Metering device ...Refrigerant restrictions will be low suction, high superheat, high subcooling. Often once you resolve the charge issue, you may also find another low load issue as well that contributed to the freezing. In many cases when low charge is the cause, the customer will notice the issue before the system is frozen solid. ...A system with low superheat and high subcooling has too much refrigerant. The two previous conditions we looked at had high superheat. Low superheat shows too much refrigerant in the evaporator, and it cannot boil it off fast enough. The excess refrigerant could easily make it back to the compressor and cause permanent damage from flood back ...The fix. How to Check For Superheat. What is subcooling and what does low subcooling mean? Chart for low subcooling causes and possible fixes. 1) Defective …Mortgage rates began plunging when COVID-19 began sweeping the globe and the Federal Reserve dropped rates in response. Several other issues factored in, too. So how low can rates ...This causes high compression ratios and low volumetric efficiencies, which results in low refrigerant flow rates. In summary, there are seven symptoms or telltale signs of a system that has too much refrigerant. High discharge temp. High subcooling in the condenser. High pressures in the condenser.High suction pressure. One sign of low subcooling is high suction pressure in your HVAC system. When there’s not enough subcooling, the refrigerant pressure in the system can become elevated, which can lead to poor cooling performance and potential damage to your system. Low discharge pressure. Low discharge pressure is another sign of low ...May 25, 2013 ... Comments265 ; Why and How to Adjust a TXV / TEV. HVAC School · 413K views ; Superheat and Subcooling Explained! How to Easily Understand! AC ...Subcooling (R-134A) = 88°F - 82°F = 6°F. We see that in this system, we have 6°F R-134A subcooling. With this subcooling formula and calculator, you can pretty much calculate subcooling for any refrigerant. The R-22, R-410A, and R-134A subcooling calculation examples are here to help you out.Freezer superheat and subcooling. Hello HVAC tech I am working on a walk in freezer box temp is -10 degrees. this is a R402A refrigerant unit by Larkin it is a Copeland compressor. My suction temp. at the compressor is 33.7 the saturated temp is -32 at 10 psi. the High side is 215 psi saturated temp 89 degrees and the pipe temp is 91 degrees ...Jul 8, 2022 · High superheat low subcooling is when there is a limited flow of refrigerant in the evaporator and a limited flow of the refrigerant in the condenser. It is worth noting that in systems with liquid line receivers, subcooling will not increase because the liquid will go to the receiver instead of the condenser although the receive line filter is ... This will cause the compressor superheat to be high. The 100 percent saturated vapor point in the evaporator will climb up the evaporator coil, causing high superheats. Low Amp Draw High compressor superheats and low suction pressures cause low-density vapors to enter the compressor.Attach the Manifold Gauges. Connect the manifold gauges to the low-pressure port. Ensure it is attached securely to prevent any leakages and to get accurate readings. Take Temperature and Pressure Readings. Using a thermometer, take the temperature reading of the suction line — this is the line that carries the refrigerant back to the unit.Share this Tech Tip: Suction pressure, head pressure, subcooling, superheat, delta T. Taking all five of these calculations into account on every service call is critical. Even if you must do further diagnostic tests to pinpoint the problem, these five factors are the groundwork before more effective diagnostics can be done.Oct 29, 2022 · The increase in temperature above saturation is described as the refrigerant’s superheat value. For example, at 18.42 psig, R-134a has a saturation temperature of 20°F. If its measured temperature is 30°F, the refrigerant is said to be superheated by 10°F. One useful area to measure the refrigerant’s superheated value is at the exit of ... May 28, 2003 · A solid understanding of superheat and subcooling is essential. Troubleshooting often requires simultaneous knowledge of temperature, pressure, voltage, and current values in a system. A single-function meter won’t permit a complete analysis of the system. Frequently, multiple tools are required. This article provides information on ... I come back the next day expecting to have to pull charge out and the subcool being way high. The unit cooled the house down to 70 it’s probably 85 outside. These are my readings 296psi high side, 95.8 lstat, 93.6 line temp, 2.3 subcool. 140.6psi low side, 50.1 vstat, 51.3 line temp, 1.2 superheat. 20degree delta tee across the return and supply.Study with Quizlet and memorize flashcards containing terms like The technician finds a high split across an evaporator coil this is an indicator of what?, The technician observes low gauge pressures on an AC unit this is an indicator of?, You find superheat by subtracting suction temperature from suction pressure T/F? and more.With the Superheat/Subcool Calculator off, press the POWER button. 2. Press and hold the UNITS button for two to three seconds until the current temperature unit is displayed. 3. Use or to select the desired temperature unit. ... For SuperHeat or Low Side PT Data For SubCool or High Side PT Data. Title: 405199_Rev.D Created Date:catching debris. we want a TXV to operate and equilibrium true or false. true. where do we look for a TXV to determine if used superheat or subcooling. SC.. indoor evaporator. if we have a TXV and the system do we superheat or subcooling and why. subcool becau2se the job of the TXV is to maintain 10 degrees of superheat the unit could be under ...1. Low Refrigerant Charge (Most Common Cause) The most common cause for high superheat is low refrigerant charge. Namely, if our AC unit doesn’t have enough freon, you will see that the metering device will underfeed the evaporator coil. Now, there is not enough refrigerant in the evaporator coil.Find helpful customer reviews and review ratings for Xetron HVAC Digital Manifold Gauge 1/4" SAE, 2 Wired Temp clamp Probes, Temp. Compensation, High/Low Side Subcool Superheat for A/C R410a R134a R22 etc at Amazon.com. Read honest and unbiased product reviews from our users.Enjoy both affordable accommodations and super high-end resorts during the same vacation with this "high/low" strategy. Update: Some offers mentioned below are no longer available....This causes high compression ratios and low volumetric efficiencies, which results in low refrigerant flow rates. In summary, there are seven symptoms or telltale signs of a system that has too much refrigerant. High discharge temp. High subcooling in the condenser. High pressures in the condenser.Superheat gives us a look at how well we are matching refrigerant flow to heat load. High superheat means evaporator underfeeding; low superheat means overfeeding. There is an issue, though. We could have a correct superheat and still have a coil temperature of under 32°—this is unacceptable in an air conditioning system.The difference between a low-context and a high-context culture lies in the mode of communication that takes place at the individual dialogue level. In low-context cultures, such a...Jul 24, 2019 · Share this Tech Tip: Suction pressure, head pressure, subcooling, superheat, delta T. Taking all five of these calculations into account on every service call is critical. Even if you must do further diagnostic tests to pinpoint the problem, these five factors are the groundwork before more effective diagnostics can be done. Buy HIATSU Digital Manifold Gauge HVAC Refrigeration Heavy Duty with 2 Wired Temperature High Low Side Pressure Measurement Superheat Subcooling 3 Hose Refrigeration Support 88 Types of Refrigerants: Air Conditioning Line Repair Tools - Amazon.com FREE DELIVERY possible on eligible purchasesSuperheat determines by how many degrees of temperature refrigerant vapor increases in the system. We are usually looking for 7°F to 15°F superheat.Too low superheat (below 2°F) = Risk of flooding the compressor, too high superheat (above 15°F) = Risk of overheating the compressor.More about that in our general superheat and subcooling …Subcooling degrees are figured by taking the difference between the discharge saturation temperature and the discharge line temperature. The amount of subcooling for optimum operation should be specified by the equipment manufacturer. An overcharged system will have low superheat, potentially allowing liquid refrigerant to damage the compressor.If superheat is high and sub-cooling is high: Could have blockage in coil, orifice or line set. If superheat is low and sub-cooling is low: Orifice could be too big, there is no orifice in the unit of the orifice is stuck and refrigerant is by-passing it. Superheat is telling you what is going on in the evaporator.In summary, here are the seven symptoms or telltale signs of a system low on refrigerant: Medium to high discharge temperatures; High evaporator superheat; High compressor superheat; Low condenser subcooling; Low compressor amps; Low evaporator temperatures and pressures; and. Low condensing temperatures and pressures. Publication date: 7/2/2018.The less refrigerant flowing through the system, the less the suction line of the system will cool off. You can have a warm suction line (high superheat) due to low charge, a restriction, or high airflow. This indicator is one of many that you need to consider when diagnosing refrigerant problems. Looking at the pinched hose example, we can see ...Superheat is high. How is charge? Low. Subcool is low. How is charge? Low. Comp amps are low. How is charge? Low. Delta T is low. How is charge? ... How is charge? Over. Superheat is high. How is charge? Over. Subcool is high. How is charge? Students also viewed. Abbréviation Autorisation ATC. 88 terms. alexmblanchet. Pubs Test Review. 31 ...To measure liquid subcooling: 1. Attach your gauge manifold to the liquid line service port. If you use a quick-connect fitting on the end of your hose, make sure it’s a low-loss fitting. I’ve seen some quick-connect fittings that allow pressure loss, which can cause inaccuracies in the charging procedure.High superheat low subcooling on a TXV system means that there is no sufficient amount of refrigerant in the evaporator and there is low amount of the refrigerant in the condenser unit. This condition is mainly caused by low charge in an air conditioning system and can be fixed by sealing leaks and adequately charging the system with a refrigerant.High subcooling and normal superheat readings provide valuable insights into the efficiency and functionality of HVAC systems. These diagnostic measures play a crucial role in determining the refrigerant charge and heat transfer processes within the system.New Guys: know your superheat & subcooling like the back of your hand & know how to calculate it without digital gauges. DON'T BE THAT GUY!!!IF YOU HAVE ANY ...I had posted in a previous thread about the superheat reading taken on my system being about 11 *F too low (possible overcharge). Today another tech came out and measured everything again. This tech measured the subcooling as well this time. Here are the measurements he took: OAT DB: 68 *F Low side: 68 psi (39 *F) High side: 140 psi …D. a liquid and a solid. D. The greater the difference in temperature between the evaporator and the air being cooled, ______________. A. the less moisture will be removed from the air. B. the less moisture will be added to the air. C. the more moisture will be added to the air. D. the more moisture will be removed from the air.Superheat is measured as the difference between the actual temperature of refrigerant vapor at a certain point and the saturation temperature of the refrigerant. It’s not complicated, but for a beginning tech, it might be.”. Superheat may be so complicated just because of the term “heat,” Tomczyk said. “Because something can be minus ...Maryland. Posts. 9. Post Likes. Low Subcooling Low Superheat? I am working on a two stage heat pump with a varable speed air handler. The system runs about 1.5 deg S/C and about 2 deg S/H The delta T is 22 deg. A capacity check shows systems is operation at 122% of publish Capacity. Adding refregerant does not change the S/C much at all.Calculate. This free online tool allows HVAC professionals to quickly calculate Superheat and Subcooling measurements for both R22 & R410A refrigerants.Find helpful customer reviews and review ratings for Xetron HVAC Digital Manifold Gauge 1/4" SAE, 2 Wired Temp clamp Probes, Temp. Compensation, High/Low Side Subcool Superheat for A/C R410a R134a R22 etc at Amazon.com. Read honest and unbiased product reviews from our users.2 degree drop across drier is acceptable (1-3 degrees in most cases) I-packs run about 17-20 degrees subcool. Superheat should always be monitored, but do not charge by superheat. Do not rely on your site glass to determine charge. You can use it as reference, but a clear site glass does not mean clean bill of health.The less refrigerant flowing through the system, the less the suction line of the system will cool off. You can have a warm suction line (high superheat) due to low charge, a restriction, or high airflow. This indicator is one of many that you need to consider when diagnosing refrigerant problems. Looking at the pinched hose example, we can see ...6. Rep Power. 36. 9 superheat & subcooling scenarios. LOW CHARGE = High superheat. Low suction pressure, indoor TD, subcooling, head pressure & …Jul 18, 2020 · Elevated suction, low superheat, lowish head and low subcooling are typically symptoms of an overfeeding metering device. But 10 SC and 7 SH are reasonable numbers though 7 SH is probably lower than necessary. I'm guessing valve is non-adjustable... With the Superheat/Subcool Calculator off, press the POWER button. 2. Press and hold the UNITS button for two to three seconds until the current temperature unit is displayed. 3. Use or to select the desired temperature unit. ... For SuperHeat or Low Side PT Data For SubCool or High Side PT Data. Title: 405199_Rev.D Created Date:thread403-449801. We have a residential R134a air-conditioning system coupled with a R134a based heat engine. The engine and the compressor are mechanically coupled. Based on our tests, the cooling output produced is about 0.07 kW (air side) and the system efficiency is about 2% (at 35 C outdoor temperature). We tested at 35 C and 25 C outdoor ...Every 24 hours and 50 minutes, the Earth experiences two high tides and two low tides. High tides occur every 12 hours and 25 minutes. From high tide to low tide is a span of six h...Hi, sorry you're having trouble. Low suction and high head is usually due to a restriction in the liquid line. Basically, you're starving the evaporator. If the unit has an expansion valve on the inlet to the evaporator, it may be defective. Some are adjustable, most residential ones, not. I would look there first.Robo stated it clear, the normal superheat for a residential system can and will vary and some charts go even further than he stated 2-45 degrees. That answer above drives the point, if you do not know the evaporator load, you can not predict the superheat. Reply. 06-02-2011, 06:58 PM #14. hvacvegas.Here is where one of the key differences between Superheat and Subcool come into play. With Subcool the gauge/saturation temperature is going to be higher then your line temperature. (Remember, with Superheat your line temp should always be higher then gauge.) Once you have these two readings you then do the math. For example.Subcooling: It's the process of cooling refrigerant below its saturation temperature. Subcooling increases the efficiency of your HVAC system by making sure the refrigerant is fully condensed before it enters the evaporator. Superheat: This is when the refrigerant gets heated above its boiling point. Superheat prevents liquid refrigerant from ...low Suction press / low suct line temp indicates low air flow through evap. coil. But, 245# head on 78 degree day seems a little high, especially with only 60# suct. Of course 78 'f' outside is going to make yur condenser very efficient, so the increased subcooling could be attributable to the OAT.A high superheat is an indication of either a low refrigerant charge or a liquid line restriction problem. To tell the difference between the two problems, we look at subcooling. A system with a low refrigerant charge will have a low subcooling. A system with a liquid line restriction will have a normal to high subcooling.Therefore the Superheat will be high when the charge is low (assumes cap tube). A low charge also lowers the head pressure (and corresponding saturation temperature). The gas takes longer to condense due to extra heat. This leaves less time for subcooling at condenser exit, hence a low subcooling reading. Sound good?The high-pressure (HP) setting for R404A can vary depending on the specific refrigeration system and its operating conditions but typically falls between 200 and 250 psi. What is the ideal range of subcooling? The ideal range of subcooling for R404A is generally around 10 to 20 degrees Fahrenheit.A subcooling value would be helpful. Reply . 08-02 ... can mask a low charge scenario. The high head leads to poor heat rejection and the higher pressures can force more of the available refrigerant into the evaporator and show up as normal or high suction pressure with normal or low superheat. Also make sure the outdoor fan motor is …Lots of people saying check airflow, but low airflow cannot lead to high superheat. The refrigerant is entering the evaporator at 23°, but it's 70° by the time it leaves. What is warming it up, if not airflow? The only realistic way to have both high superheat and low subcool is low charge.Here's Where Lowe's (LOW) Stands After Earnings Are Released...LOW Shares of home improvement retailer Lowe's Companies (LOW) are slumping in early trading after the compan...This will cause low subcooling and low head pressure. Here are the seven telltale signs of a system low on refrigerant: Medium-to-high discharge temperatures; High evaporator superheat; High compressor superheat; Low condenser subcooling; Low compressor amps; Low evaporator temperatures and pressures; and; Low condensing …That and the high subcool makes me think it cannot be low on refrigerant just because the superheat is high. I think the other technician was correct. The condenser was dirty or there was a restriction. Adding refrigerant was not really the answer although it worked.Study with Quizlet and memorize flashcards containing terms like Compressor overheating Low subcooling High head pressure, Higher energy bills Longer run time increased wear and tear on the compressor, Liquid refrigerant is present in your oil have low superheat and more.Bumping is an occurrence in chemistry where liquids boiled in a test tube superheat before undergoing a sudden release of vapor, expelling the liquid from the container. Bumping is...Low subcooling means that a condenser is empty. High subcooling means that a condenser is full. Overfilling a system increases pressure due to the liquid filling of a condenser that shows up as high subcooling. To move the refrigerant from the condenser to the liquid line, it must be pushed down the liquid line to a metering device.Subcooling. The term subcooling (also called undercooling) refers to a liquid existing at a temperature below its normal boiling point. For example, water boils at 373 K; at room temperature (293 K) liquid water is termed "subcooled". A subcooled liquid is the convenient state in which, say, refrigerants may undergo the remaining stages of a ...Indoor unit calls for a 070 piston. This piston in it is 067. Condenser only references TXV, doesn't specify a piston size. Subcool is approx 10, superheat is in the 40's. Comp amp draw is below RLA, suction pressure is low (gauges show a 20 degree coil, but no ice or sweating is occurring), and head pressure is slightly low.The fix. How to Check For Superheat. What is subcooling and what does low subcooling mean? Chart for low subcooling causes and possible fixes. 1) Defective metering device. The fix. 2) Poor compression. The fix. 3) Refrigerant Undercharge. 4) Restricted airflow to the condenser. The fix. How to Check Subcooling.This is important because, in cool mode, a dirty air filter caused low airflow on the evaporator. In those cases, you would typically notice a low suction pressure and a low superheat. In heat mode, a dirty air filter causes low airflow across the condenser. That can cause extremely high head pressure. In heat mode, a dirty outdoor coil can ...Well, 304-psig is 96-F SCT, therefore the suction line would have to be 89-F to get 7-F subcooling. A 156-psig is 55-F SST, a 56-F suction line would be around 1-F superheat. Many heat pumps use 10 to even 7-F TXV superheat. Appears beenthere nailed it, you appear to be using the pressure saturation temps.Boiling stones are pieces of mineral put in a solution and heated in a round-bottomed flask so that boiling will be even. Without boiling stones, liquids heated in such flasks have...Dec 1, 2023 · On the flip side, high superheat might indicate low refrigerant levels or poor airflow across the coil. Again, catching these early helps prevent bigger headaches down the road. So yeah, measuring superheat and subcooling regularly is like giving your HVAC system a longer lease on life. By keeping an eye on both subcooling and superheating, you can optimize your refrigeration system's efficiency, prolong its life, and minimize energy consumption. Navigating through this hub page, you have learned the importance of maintaining the ideal superheat range, as both high and low superheat can cause potential problems in your system.Let's take a look at other possible causes. Low suction pressure problems can be divided into two subcategories — low suction/high superheat and low suction/low superheat: Low suction/high superheat: Moisture, dirt, or wax buildup in critical areas, especially the metering device. In Figure 6, this fixed metering device is 30% blocked.How to measure SUPERHEAT and SUBCOOLING! HVAC/R Training Video.How to calculate SUPERHEAT and SUBCOOLING on your air conditioner or refrigerator? R22 R410a R...Head pressure: 118F 83 + 35 = 118F more or less shows on the high side gauge if I understand this correctly. Low side pressure: 125 psi = 42 saturation temp. 66.2 low side line temp. High side pressure: 335psi = 104 saturation temp. 83.1 high side line temp. Temp at the vent in rooms: 56.1F + or minus. Temp from supply side: 55.2F.Superheat and subcooling data can help you pinpoint these issues quickly. Common Causes of Superheat and Subcooling Imbalance. Common reasons for superheating and subcooling include issues such as liquid line restriction, malfunctioning metering systems, and limited airflow, all of which can lead to high superheating and low subcooling levels. 1.

28. Post Likes. high super heat low suction. any ideas. I am working on a ruud heat pump. Freeze up problems. Low suction pressure, 24 superheat, 8 subcooling. 14 degree air drop across my coil. I have evacuated and wieghed in a charge r-22 and replaced txv. No kinks in line set and not a plugged filter dryer. .5 static pressure across my coil.. Lorex cloud not connecting

low subcool high superheat

This will cause the compressor superheat to be high. The 100 percent saturated vapor point in the evaporator will climb up the evaporator coil, causing high superheats. Low Amp Draw High compressor superheats and low suction pressures cause low-density vapors to enter the compressor.Hey my fellow tech. I recieved a call today that the unit was freezing over on a old carrier unit. So i went through the protocol, IDM, Filter, Evap coil, ductwork, all checked out good. Before i continue recommend every tech to go get the testo 550 they're so nice. Anyhow hooked up my testo to the unit the unit and checked my superheat sence it had cap tubes.Identifying the low-pressure. Now let's check the subcooling on the evaporator unit. Start by locating the low-pressure service valve - it's usually near the suction line, which is the larger of the two copper pipes. ... Signs of incorrect subcooling can include high superheat, inefficient system performance, and excessive compressor wear ...Low suction pressure and high head pressure is a condition where there is a decreased refrigerant pressure in the AC system and at the same time a high output pressure in a compressor. This condition is mainly caused by a defective or malfunctioning TXV valve. An expansion valve is a device that regulates the flow of the liquid refrigerant …Unfortunately, there is a lot of misunderstanding as to what exactly Superheat and Subcool actually are and even less understanding on how to measure it. There are so many novice technicians that get 'stumped' on a system without even checking Subcool or Superheat temperatures…. or if they did check them they checked in the wrong section.The increase in temperature above saturation is described as the refrigerant’s superheat value. For example, at 18.42 psig, R-134a has a saturation temperature of 20°F. If its measured temperature is 30°F, the refrigerant is said to be superheated by 10°F. One useful area to measure the refrigerant’s superheated value is at the exit of ...If I have my theroy right I have a low superheat of 10 and a high subcooling of 21. Ambiant temp outside is 81 and all temps are in F. 19-07-2011, 03:16 AM #40. Gary. View Profile View Forum Posts View Blog Entries Visit Homepage View Articles VIP Poster Join Date Apr 2001 Location New Port Richey, Florida - USA ...High superheat= not enough refrigerant in the evaporator. Low subcool= not enough refrigerant in the condenser Compression ratio is fine, unlikely to be the valves. It isn’t possible for you to have liquid refrigerant in the liquid line if the line is hotter than the boiling point of the refrigerant. A Negative subcool number is not a thing.Post Likes. Low subcooling results when there is insufficient refrigerant to fill the lower part of the condenser coil. High suction superheat results when there is insufficient refrigerant to fill the evaporator properly. If you have insufficient refrigerant in both places - it is likely that the system is undercharged.If the actual subcooling is higher than the target subcooling, the unit’s refrigerant charge level is overcharged. Some refrigerant will need to be recovered into a recovery bottle. • Actual Subcooling +/-3° F Target Subcooling = Correct Refrigerant Level. • Actual Subcooling < Target Subcooling = Add Refrigerant.Take the condensing temperature and the condenser outlet temperature, and the difference between the two is the amount of subcooling. "Let's say the condensing temperature is 100°F. Put a thermistor on the condenser outlet, and let's say that's 90°," continued Tomczyk. "So, you have 10° of subcooling. Technicians get confused ...Feb 13, 2016 ... Comments19 · Class - What Superheat Signifies · How to Read SUPERHEAT and SUBCOOLING · Chiller had high SUPERHEAT cause of this · Refri...It has to do with the balance of refrigerant within the system; between the low and high side. Low superheat with high sub-cooling generally indicates over charge. Too much liquid refrigerant in both sides. High superheat with low condenser sub-cooling generally indicates an under charge. Not enough liquid on either side.Indoor unit calls for a 070 piston. This piston in it is 067. Condenser only references TXV, doesn't specify a piston size. Subcool is approx 10, superheat is in the 40's. Comp amp draw is below RLA, suction pressure is low (gauges show a 20 degree coil, but no ice or sweating is occurring), and head pressure is slightly low.This will result in high suction pressure, low superheat, and low subcooling. In these cases, the piston should be removed and inspected for the proper bore size and signs of contamination around the outside or near the seal surfaces of the piston and the housing..